Home About us News References Contact Sitemap Partners Deutsch  
Analysers
Copper (Cu)
Chromate (Cr)
Cyanide (CN)
Iron (Fe)
Lead (Pb)
Manganese (Mn)
Nickel (Ni)
Zinc (Zn)
Others
Applications
Potable water
Waste water
Process water
Tunnelling
Watercourse-
  protection
Piperoof
  grouting 
Telemetry
Engineering
Dosation
Control
  engineering
Top of page

 Further analysers available
 - Ammonia (NH3)
 - Chloride (Cl2)
 - Fluoride (Fl)
 - Iodide (I)
 - Sulfide (S-)
 - General technical information
 Ammonia (NH3)
Measuring range   0.005 ... 2.0 mg/l NH3 (low range)
    0.5 ... 50.0 mg/l NH3 (high range)
Resolution   0.01
Accuracy   +/- 2% (based on full scale)
Measuring interval   Continuous
    Discontinuous/programmable
    External start
Measuring method   Ion selective electrode
Reagents   2
Calibration   Automated
Cleaning   Automated
Interferences   Hg, Cu, Zn, Cd, Co, Ni, Au, Ag
    Interfering ions can be masked in local applications.

Top of page
 Chloride (Cl2)
Measuring range   0.1 ... 10.0 g/l Cl
Resolution   0.01
Accuracy   +/- 3% (based on full scale)
Measuring interval   Continuous
    Discontinuous/programmable
    External start
Measuring method   Ion selective electrode
Reagents   3
Calibration   Automated
Cleaning   Automated
Interferences   Bi, Cd, Mn, Pb, Sn, Tl
    Interfering ions can be masked in local applications.

Top of page
 Fluoride (Fl)
Measuring range   0.2 ... 2000 mg/l F
Resolution   0.1
Accuracy   +/- 2% (based on full scale)
Measuring interval   Continuous
    Discontinuous/programmable
    External start
Measuring method   Ion selective electrode
Reagents   1
Calibration   Automated
Cleaning   Automated
Interferences   OH=0.1
    Interfering ions can be masked in local applications.

Top of page
 Iodide (I)
Measuring range   0.005 .. 1.0 mg/l I-
Resolution   0.01
Accuracy   +/- 3% (based on full scale)
Measuring interval   Continuous
    Discontinuous/programmable
    External start
Measuring method   Ion selective electrode
Reagents   2
Calibration   Automated
Cleaning   Automated
Interferences   Cl, Br, S-, CN, S2O3
    Interfering ions can be masked in local applications.

Top of page
 Sulfide (S-)
Measuring range   0.02 ... 50.0 mg/l S-
Resolution   0.1
Accuracy   +/- 3% (based on full scale)
Measuring interval   Continuous
    Discontinuous/programmable
    External start
Measuring method   Colourimetric
Reagents   2
Calibration   Automated
Cleaning   Automated
Interferences   Hg, Cu, Zn, Cd, Co, Ni, Au, Ag
    Interfering ions can be masked in local applications.

Top of page
 General technical information
Power supply   230 VAC, 50 Hz (110 VAC optional)
Current consumption   Max. 50 VA
Switch contacts   2 x P-controlled (min, max)
    1 x alarm contact
Analogue output   4..20 mA
Digital output   RS232 C
    Options: Interbus-S, Profibus, CAN
Cabinet size   746 x 600 x 373 mm (HxBxD)
Weight   App. 80 kg
Environmental temperature   +15°C .. +35°C
Humidity   Max. 70% RH, no condensation
Sample pressure   0 .. 0.5 bar
Sample inlet   6/4 mm hose
Sample drain   Unpressurised, free falling, 6/4 mm hose

Top of page
SEIBOLD-Messtechnik und Projektentwicklug GmbH, A-1110 Wien, Grillgasse 51